Autochlor Electrochlorinator


 
The Autochlor system is compact and can produce Sodium Hypochlorite continuously. This is a wall mounted compact model with automatic control.System stops when the hypo storage tank is full.
 
  •  
Smaller – easier to install in confined spaces
  •  

Requires less manpower and human intervention.

  •  
Uses less power. Unit more efficient than conventional chlorinators (switch mode power supply)
  •  
Better weather proofing, corrosion proof.
  •  
Lesser moving parts, so less wear and tear and longer life.


Application

1
Small to Medium water treatment facilities for disinfection of drinking water
2
Small Waste water, Effluent and Sewage treatment.
3 Medium sized Hotels, Hospitals, Educational institutions for Drinking water.
4 Disinfection in small Water parks, Cooling water circuits, Fire water storage tanks.
 
System Specification:

Model No.
PCP10
PCP15
PCP25
PCP 50       
PCP100
Active Chlorine  Generated                              
10Grams/hr
15Grams/hr
25Grams/hr
50Grams/hr
   
100Grams/hr
Process
Continuous
Continuous
Continuous
Continuous
Continuous
Hypochlorite Strength
6 -8.0 Gpl
6 -8.0 Gpl
6 -8.0 Gpl
6 -8.0 Gpl
6 -8.0 Gpl
Water Consumption
1.5liter/hr
2liter/hr
2.5liter/hr
7liter/hr
14liter/hr
Salt Consumed
 
50grams/hr
70grams/hr
120grams/hr
200grams/hr
400grams/hr
Power Consumed
0.500kwh/hr
0.700kwh/hr
0.900kwh/hr
1.600kwh/hr
2.800kwh/hr
AC current Input
230V, 50 Hz
230V, 50 Hz
230V, 50 Hz
230V, 50 Hz
230V, 50 Hz
 
 Operation
  1.  Water is to be filled through the float valve up upto the marked level.
  2. Put good clean salt and mix properly.
  3. Mix the salt properly.
  4. Switch on the power supply.
  5. The brine metering pump will start and pump  brine into the Electrolyzer
  6. The DC current applied across the anode and cathode of the cell will start the Electrolysis reaction in the diluted brine solution.
  7. Now the cell converts the brine solution into Sodium Hypochlorite
  8. The Sodium Hypochlorite (NaOCl) will flow out through a tube into the NaOCl tank.
  9. The NaOCL tank is provided with a level controller
  10. Once the NaOCL reaches the upper limit the level controller will stop the Electro Chlorinator System.
  11. A NaOCL metering pump is independent of the system.
  12. The out let of the NaOCl pump is connected to the dosing point.
  13. As the level of NaOCl reduces due to the dosing, the level controller will restart the system

 
 
We can offer higher capacity models, for details please  contact us
   
Disinfectant Generator
Portable Chlorine Generator
Floor Mounted Chlorine Generator
Portable Solar Chlorinator
Solar Chlorinator
Continuous Production Electrochlorinator
Seawater Electrochlorinator
Swimming Pool Chlorinators
 
 

 

© 2007, All Right Reserved